83NbNiobium
Z:  
Z = 41N = 42
N:  

Setting ID1 Yield 2
[pps/pnA]
Measurement
date
Beam Target Brho01
[Tm]
F1 slit
L [mm]
F1 slit
R [mm]
Data from
301.55e+12016-04-29124Xe 345MeVBe 4mm5.460064.20.0Phys. Rev. Lett. 119, 192503 (2017)
311.66e+12016-04-29124Xe 345MeVBe 4mm5.460042.842.8Phys. Rev. Lett. 119, 192503 (2017)



Publication
Title Journal First Author
Precision Mass Measurements around 84Mo Rule Out ZrNb Cycle Formation in the Rapid Proton-Capture Process at Type I X-Ray BurstsPhys. Rev. Lett. 135, 152701 (2025)S. Kimura


 Annotations:
1 Detailed BigRIPS setting is shown in the linked page.
2 The list of primary beam intensities is given in this page.
3 Error is only statistical one. Systematic error is estimated within 30%, which comes from uncertainly of primary beam intensity.


Return