48CaCalcium
Z:  
Z = 20N = 28
N:  

Setting ID1 Yield 2
[pps/pnA]
Measurement
date
Beam Target Brho01
[Tm]
F1 slit
L [mm]
F1 slit
R [mm]
Data from
161.15e+22016-11-07238U 345MeVBe 1mm6.800021.450.0 ---
193.06e+12016-11-06238U 345MeVBe 10mm7.253950.050.0 ---
1422.95e+12012-07-0970Zn 345MeVBe 10mm6.54905.05.0 ---
2521.50e+22007-05-28238U 345MeVBe 7mm7.250021.021.0J. Phys. Soc. Jpn. 77, 083201 (2008)
2543.23e+02007-05-23238U 345MeVBe 7mm7.396021.021.0 ---



Publication
Title Journal First Author
Charge-changing cross sections for 42–51Ca and effect of charged-particle evaporation induced by neutron-removal reactionsPhys. Rev. C 106, 014617 (2022)M. Tanaka
Swelling of Doubly Magic 48Ca Core in Ca Isotopes beyond N = 28Phys. Rev. Lett. 124, 102501 (2020)M. Tanaka

Experiment
Proposal No. Spokesperson Start-Date End-Date Beam Course
NP1912-RIBF170R1H. Crawford2020-12-072020-12-1170Zn 345 MeV/u ZeroDegree
NP1512-RIBF79R1-02J. Zenihiro2019-11-192019-11-25238U 345 MeV/u F12
NP1512-RIBF79R1J. Zenihiro2016-05-152016-05-25238U 345 MeV/u F12


 Annotations:
1 Detailed BigRIPS setting is shown in the linked page.
2 The list of primary beam intensities is given in this page.
3 Error is only statistical one. Systematic error is estimated within 30%, which comes from uncertainly of primary beam intensity.


Return